PANASONIC KX-T7885

KX-T78852.jpg (10621 bytes)

features

Cordless Technology 900 MHz
Flexible Keys with Indicators Yes
Spare Battery Charger Yes
Auto Channel Scanning 30
Station Speed Dialer 22
Handset Locator Yes
Sound Charger Noise Reduction Technology Yes
3-Line Multi-Function LCD Readout Yes
Handset Belt Clip Yes
Caller ID Compatible1 Yes
6 Ringer Modes Yes
Combination Buttons Yes
Wall-Mountable Base Antenna Yes
High Capacity, Quick recharging NI-MH Battery Yes
Message Waiting Indicator Yes
Available in Black or White Yes
Convenient Quick-Release Swivel Belt Clip Yes
FWD, DND, Redial, Transfer and Hold Keys Yes

 

 

HAIPROMO11


AUTOMATION FEATURES

  • Controls up to 26 different lights, appliances or groups: 16 via power line carrier control modules or optional ALC hardwire lighting
    modules, 2 (expandable to 10) hardwired to OmniLT controller
  • Temperature control for 2 HAI Omnistat thermostats
  • Dedicated thermostat interface (does not use a zone or output) sends time, outdoor temperature to thermostats for display
  • Time, Sunrise, Sunset, outdoor temperature display
  • Status display (On, off, level, mode, heat, cool, fan, temperature, etc.)
  • Temperature control for other items or existing thermostats using up to 8 Temperature Sensors or PESMs
  • 2-Way X-10 allows OmniLT to receive signals for use as program triggers, features collision detection and retry for reliability
  • Lights can be set to scenes of varying brightness, with Direct Dim and Scene Support for advanced home theater lighting control
  • Lights, control outputs, temperatures and security modes can be scheduled by time, sunrise, sunset, and date or day of week and
    various system events.
  • 100 lines of non volatile control program storage
      
  • Commands (immediate and scheduled) include:
    • on, off, dim, brighten, level, (and ramp rate for ALC)
    • timed on, off, dim, bright
    • change settings, mode, fan for thermostats
    • change system modes, zone status, flags
    • display a message on console, place a phone call
    • activate a button (macro)  
        
  • Event button capability ("Scenes" or "macros") allows a series of commands to be executed at once, to create lighting scenes,
    house modes, adjust temperatures, etc., initiated by: 
    • a console command
    • a telephone command
    • a zone opened or closed
    • a mode change (i.e. day, away vacation)
    • a particular user code entered
    • a time schedule
    • other internal or external events
       
  • Scheduling commands and Event buttons can be conditionalized (made to execute only if the condition is true) by sunrise/sunset,
    time clocks, zones open or closed, mode, flags, more
  • Expansion port for future CEBus, Echelon or other interface 

< Back to List


SECURITY FEATURES

  • 8 Zones, expandable to 24, fully configurable for:
    • full selection of security zone types
    • outdoor temperature
    • energy saver module
    • temperature control and/or alarm
    • auxiliary input for automation use (without security)
    • keyswitch
    • zone 8 supports 2 and 4 wire smoke detectors
        
  • 2 Hardwire Outputs, expandable to 10, fully configurable for:
    • control output for automation
    • smoke detector power and reset
    • temperature control
    • long range radio
    • armed, OK to arm, and others
        
  • LCD Consoles
    • surface, flush and universal models available.
    • 4 wire connection, independent operation, 4 maximum.
    • configurable beeper, viewing angle, backlighting
        
  • Five modes: off, day, night, away, vacation
  • 8 user codes with selectable authority levels
  • User codes can be made valid during certain times and days only, for maid, service, etc.
  • All lights on when alarm is tripped to frighten intruder away
  • Outdoor lights flashing when alarm is tripped to alert neighbors and police
  • Entry and Exit delays user programmable
  • Entry delay can be doubled or quadrupled on a zone to accommodate garage and back doors.
  • Pre-alarm beeper in console gives owner time to turn alarm off before outdoor siren is activated
  • Supervised siren output detects shorted or cut wire to siren 
  • System Announces type and location of alarm with optional 2-Way Voice Module
  • Auto bypass feature means alarm won't go off unexpectedly if door or window is left open when the system is armed.
  • Trouble conditions indicated in English on display for: zone and system trouble, AC Power off, battery low, phone line dead
  • Optional wireless receiver is fully supervised for greatest reliability 
  • High Security mode for commercial applications
  • All Fire and Burglary zones are fully supervised
  • Event Log with Time & Date

< Back to List


TELEPHONE CONTROL FEATURES

  • Works with Touch Tone phones inside or away from the premises with access code
     
  • Compatible with answering machines, answering services
     
  • From any phone, you can:
    • change modes
    • change temperatures
    • arm/disarm security, bypass and restore zones
    • activate macro buttons
    • hear complete status of system
    • hear event log and help menu
    • Lockout feature discourages tampering with system by phone
    • Listen-in / talk to premises with optional two way voice module

< Back to List


DIGITAL DIALER FEATURES

  • Contact ID, 4/2 and 3/1 formats, dual round compared
  • Two phone numbers with two account numbers
  • Opening/Closing reports by user code

< Back to List


VOICE DIALER FEATURES

  • Completely solid state, no tape or moving parts to wear or break
  • Voice dialer is delayed by 5 minutes if digital dialer is used to allow central station to call back
  • Dials up to 8 user programmable numbers and reports type and location of alarm
  • Called party can cancel dial out by entering code
  • OmniLT can call pagers, and be programmed to make a voice call based on a non-alarm event (example: call when children arrive
    home; call if "no activity" for elderly care)

< Back to List


RELIABILITY FEATURES

  • Designed for continuous trouble-free operation
  • Verifies smoke detectors by cycling power and confirming smoke alarm
  • System reads resistance of each zone independently to detect trouble due to faulty sensor or wiring before it causes false alarms
  • Pulse count feature precludes false alarms due to static, transients and lightning
  • Programmable delay to preclude false alarms from user error
  • All inputs and outputs protected against static, RFI, surges, and lightning by use of impedance limits, spark gaps, TRANZORB surge
    arrestors, RC filters, MOVs, bypass capacitors and grounded shields
  • Watchdog timer, non volatile EEPROM storage for ALL programs, self diagnostic software, low voltage cut out, self protecting power
    supply forsystem integrity

< Back to List


EASE OF USE FEATURES

  • Text descriptions for all zones, units, codes, and macros
  • Voice descriptions on telephone
  • Console display shows menus to guide users during use
  • Minimum keystrokes for common functions
  • Quick mode change feature
  • Optional wireless keyfob for arming and control available
  • Web Browser Graphical Display (HAI Web-Link II) available

< Back to List


TECHNICAL

  • Power supply: Requires 16 VAC transformer, 50/60 Hz
  • Recommended battery: 12 V, 4 Ah sealed rechargeable

< Back to List


COMPUTER INTERFACE

  • Built in Omni-Link serial interface, with jumper selectable RS-232 or RS-485. Can be used for programming, connection to HAI
    Web-LinkII, personal computers, Connectivity Partner options 
  • Built-in modem for local or remote (with security code) access to system using personal computer
  • Everything in Omni can be programmed using HAI PCAccess software for personal computer

< Back to List


OPTIONS

  • HAI Web-Link II Internet and Local Area Network software (Windows)
  • HAI PC Access configuration, monitoring and programming software (Windows)
  • 16 Zone Supervised Wireless Receiver
  • 2-Way Voice Module
  • 16 Zone / 8 Output hardwire expansion card
  • ALC Hardwire Lighting Control Module

< Back to List


APPROVALS

  • UL Residential Fire and Burglary
  • FCC Part 15J, Part 68
  • IS-60 (Canada)
  • California State Fire Marshall
  • CE (European Standard)

< Back to List


HAIPROMO12


AUTOMATION FEATURES

  • Controls up to 72 different lights, appliances or groups: 64 via power line carrier control modules or optional ALC hardwire lighting modules, 8 hardwired to Omni II controller

  • Temperature control for 4 HAI Omnistat thermostats

  • Omni II sends time, outdoor temperature to thermostats for display

  • Time, Sunrise, Sunset, outdoor temperature display

  • Status display (On, off, level, mode, heat, cool, fan, temperature, etc.)

  • Temperature control for other items or existing thermostats using up to 8 Temperature Sensors or PESMs

  • 2-Way X-10 and ALC allows Omni II to receive signals for use as program triggers, features collision detection and retry for reliability

  • Lights can be set to scenes of varying brightness, with Level, Ramp and Scene Support for architectural quality lighting control 

  • Lights, control outputs, temperatures and security modes can be scheduled by time, sunrise, sunset, and date or day of week and various system events.

  • 500 lines of non volatile ACP program storage

Commands (immediate and scheduled) include:

  • on, off, dim, brighten, level, (and ramp rate for ALC)
  • timed on, off, dim, bright
  • change settings, mode, fan for one or all thermostats
  • change system modes, zone status, flags
  • say, display or place a call with a message
  • activate a button (macro)
  • scene select
  • Supports HAI Pro-Link, which allows two-way serial communications with other controllers using ASCII messages

Event button capability ("Scenes" or "macros") allows a series of commands to be executed at once, to create lighting scenes, house modes, adjust temperatures, etc., initiated by:

  • a console, computer or telephone command
  • a zone opened or closed
  • a mode change (i.e. day, away, vacation)
  • a particular user code entered
  • a time schedule, sunrise, sunset
  • other internal or external events
  • Enhanced ACP includes new commands for "real time pricing" of energy costs, and allows two conditionals per line for easier programming 

  • Automatic Daylight Saving Time adjustment

  • Expansion port for future SCP, UPnP, LonWorks or other interface

< Back to List


SECURITY FEATURES

16 Zones, expandable to 48 zones:

  • supports two 10A06 16 zone hardwire expanders
  • HAI supervised wireless receiver (16 zones)
  • full selection of security zone types, keyswitch
  • outdoor temperature, energy saver module
  • temperature control and/or alarm
  • auxiliary input for automation use (without security)
  • all zones support 4 wire smoke detectors
  • zone 1-4 support 2 wire smoke detectors

8 Hardwire Outputs, fully configurable for:

  • control output for automation
  • temperature control
  • long range radio
  • armed, OK to arm, and others

LCD Consoles:

  • surface, flush and universal models available.
  • 4 wire connection, independent operation, 8 maximum.
  • configurable beeper, viewing angle, backlighting

Features:

  • True Partitions: security and automation can be partitioned into 2 areas

  • Five modes: off, day, night, away, vacation

  • 16 user codes with selectable authority levels

  • User codes can be made valid during certain times and days only, for maid, service, etc.

  • All lights on when alarm is tripped to frighten intruder away

  • Outdoor lights flashing when alarm is tripped to alert neighbors and police

  • Entry, Exit, outdoor sirens delays user programmable

  • Entry delay can be doubled or quadrupled on a zone to accommodate garage and back doors.

  • Pre-alarm beeper in console and separate indoor siren output gives owner time to turn alarm off before outdoor siren is activated

  • Two separate, supervised outputs for indoor and outdoor sirens

  • System Announces type and location of alarm with optional 2-Way Voice Module

  • Auto bypass feature means alarm won't go off unexpectedly if door or window is left open when the system is armed

  • Trouble conditions indicated in English on display

  • Phone line monitor

  • Optional wireless receiver is fully supervised for greatest reliability

  • High Security mode for commercial applications

  • All Fire and Burglary zones are fully supervised

  • Event Log with Time & Date

< Back to List


TELEPHONE CONTROL FEATURES

  • Works with Touch Tone phones inside or away from the premises with access code

  • Compatible with answering machines, answering services

  • Lockout feature discourages tampering with system by phone

  • Listen-in / talk to premises with optional two way voice module

From any phone, you can:

  • change modes, temperatures, macros
  • arm/disarm security, bypass and restore zones
  • hear complete status of system
  • hear event log and help menu

< Back to List


DIGITAL DIALER FEATURES

  • Contact ID, 4/2 and 3/1 formats, dual round compared
  • Two phone numbers with two account numbers
  • Opening/Closing reports by user code

< Back to List


VOICE DIALER FEATURES

  • Completely solid state, no tape or moving parts to wear or break
  • Voice dialer is delayed by 5 minutes if digital dialer is used to allow central station to call back
  • Dials up to 8 user programmable numbers and reports type and location of alarm
  • Called party can cancel dial out by entering code
  • Omni II can call pagers, and be programmed to make a voice call based on a non-alarm event (example: call when children arrive home; call if "no activity" for elderly care)

< Back to List


RELIABILITY FEATURES

  • Designed for continuous trouble-free operation
  • Verifies smoke detectors by cycling power and confirming smoke alarm
  • System reads resistance of each zone independently to detect trouble due to faulty sensor or wiring before it causes false alarms
  • Fuse-less, short-proof design
  • Programmable delay to preclude false alarms from user error
  • All inputs and outputs protected against static, RFI, surges, and lightning by use of impedance limits, spark gaps, TRANZORB surge arrestors, RC filters, MOVs, bypass capacitors and grounded shields Watchdog timer, non volatile EEPROM storage for ALL programs, self diagnostic software, low voltage cut out, self protecting power supply for system integrity

< Back to List


EASE OF USE FEATURES

  • Text descriptions for all zones, units, codes, and macros
  • Voice descriptions on telephone
  • Console display shows menus to guide users during use
  • Minimum keystrokes for common functions
  • Quick mode change feature
  • Optional wireless keyfob for arming and control available
  • Web Browser Graphical Display (HAI Web-Link II) available

< Back to List


TECHNICAL

  • Power supply: Requires 24 VAC transformer, 50/60 Hz
  • Recommended battery: 12 V, 7 Ah sealed rechargeable

< Back to List


COMPUTER INTERFACE

  • Built in Omni-Link or Pro-Link serial interface, with jumper for RS-232 or RS-485. Can be used for programming, connection to HAI Web-Link II, personal computers and Connectivity Partner options
  • Built-in v.22 bis fast modem for local or remote (with security code) access to system using personal computer
  • Everything in Omni II can be programmed using HAI PC Access software for personal computer

< Back to List


OPTIONS

  • HAI Web-Link II Internet and Local Area Network software (Windows)
  • HAI PC Access configuration, monitoring and programming software (Windows)
  • Supervised Wireless Receiver, 2-way voice module.
  • Additional Serial Board
  • 16 Zone hardwire expansion card
  • ALC Hardwire Lighting Control Module

< Back to List


APPROVALS

  • UL Residential Fire and Burglary
  • UL Commercial Burglary
  • FCC (USA)
  • ICCS-03 (Canada)
  • California State Fire Marshall
  • CE (Europe): Electromagnetic Compatibility, Emissions and Immunity