PANASONIC KX-T7885

|
|
| features |
|
Cordless Technology |
|
900 MHz |
 |
|
Flexible Keys with Indicators |
|
Yes |
 |
|
Spare Battery Charger |
|
Yes |
 |
|
Auto Channel Scanning |
|
30 |
 |
|
Station Speed Dialer |
|
22 |
 |
|
Handset Locator |
|
Yes |
 |
|
Sound Charger
Noise Reduction Technology |
|
Yes |
 |
|
3-Line Multi-Function LCD Readout |
|
Yes |
 |
|
Handset Belt Clip |
|
Yes |
 |
|
Caller ID Compatible1 |
|
Yes |
 |
|
6 Ringer Modes |
|
Yes |
 |
|
Combination Buttons |
|
Yes |
 |
|
Wall-Mountable Base Antenna |
|
Yes |
 |
|
High Capacity, Quick recharging
NI-MH Battery |
|
Yes |
 |
|
Message Waiting Indicator |
|
Yes |
 |
|
Available in Black or White |
|
Yes |
 |
|
Convenient Quick-Release Swivel
Belt Clip |
|
Yes |
 |
|
FWD, DND, Redial, Transfer and
Hold Keys |
|
Yes |
 |
|
|
HAIPROMO11
AUTOMATION FEATURES
- Controls up to 26 different lights, appliances or groups:
16 via power line carrier control modules or optional ALC hardwire lighting
modules, 2 (expandable to 10) hardwired to OmniLT controller
- Temperature control for 2 HAI Omnistat thermostats
- Dedicated thermostat interface (does not use a zone or
output) sends time, outdoor temperature to thermostats for display
- Time, Sunrise, Sunset, outdoor temperature display
- Status display (On, off, level, mode, heat, cool, fan,
temperature, etc.)
- Temperature control for other items or existing thermostats
using up to 8 Temperature Sensors or PESMs
- 2-Way X-10 allows OmniLT to receive signals for use as
program triggers, features collision detection and retry for reliability
- Lights can be set to scenes of varying brightness, with
Direct Dim and Scene Support for advanced home theater lighting control
- Lights, control outputs, temperatures and security modes
can be scheduled by time, sunrise, sunset, and date or day of week and
various system events.
- 100 lines of non volatile control program storage
- Commands (immediate and scheduled) include:
- on, off, dim, brighten, level, (and ramp rate for ALC)
- timed on, off, dim, bright
- change settings, mode, fan for thermostats
- change system modes, zone status, flags
- display a message on console, place a phone call
- activate a button (macro)
- Event button capability ("Scenes" or
"macros") allows a series of commands to be executed at once, to create lighting
scenes,
house modes, adjust temperatures, etc., initiated by:
- a console command
- a telephone command
- a zone opened or closed
- a mode change (i.e. day, away vacation)
- a particular user code entered
- a time schedule
- other internal or external events
- Scheduling commands and Event buttons can be
conditionalized (made to execute only if the condition is true) by sunrise/sunset,
time clocks, zones open or closed, mode, flags, more
- Expansion port for future CEBus, Echelon or other
interface
< Back to List
SECURITY FEATURES
- 8 Zones, expandable to 24, fully configurable for:
- full selection of security zone types
- outdoor temperature
- energy saver module
- temperature control and/or alarm
- auxiliary input for automation use (without security)
- keyswitch
- zone 8 supports 2 and 4 wire smoke detectors
- 2 Hardwire Outputs, expandable to 10, fully configurable
for:
- control output for automation
- smoke detector power and reset
- temperature control
- long range radio
- armed, OK to arm, and others
- LCD Consoles
- surface, flush and universal models available.
- 4 wire connection, independent operation, 4 maximum.
- configurable beeper, viewing angle, backlighting
- Five modes: off, day, night, away, vacation
- 8 user codes with selectable authority levels
- User codes can be made valid during certain times and days
only, for maid, service, etc.
- All lights on when alarm is tripped to frighten intruder
away
- Outdoor lights flashing when alarm is tripped to alert
neighbors and police
- Entry and Exit delays user programmable
- Entry delay can be doubled or quadrupled on a zone to
accommodate garage and back doors.
- Pre-alarm beeper in console gives owner time to turn alarm
off before outdoor siren is activated
- Supervised siren output detects shorted or cut wire to
siren
- System Announces type and location of alarm with optional
2-Way Voice Module
- Auto bypass feature means alarm won't go off unexpectedly
if door or window is left open when the system is armed.
- Trouble conditions indicated in English on display for:
zone and system trouble, AC Power off, battery low, phone line dead
- Optional wireless receiver is fully supervised for greatest
reliability
- High Security mode for commercial applications
- All Fire and Burglary zones are fully supervised
- Event Log with Time & Date
< Back to List
TELEPHONE CONTROL
FEATURES
- Works with Touch Tone phones inside or away from the
premises with access code
- Compatible with answering machines, answering services
- From any phone, you can:
- change modes
- change temperatures
- arm/disarm security, bypass and restore zones
- activate macro buttons
- hear complete status of system
- hear event log and help menu
- Lockout feature discourages tampering with system by phone
- Listen-in / talk to premises with optional two way voice
module
< Back to List
DIGITAL DIALER FEATURES
- Contact ID, 4/2 and 3/1 formats, dual round compared
- Two phone numbers with two account numbers
- Opening/Closing reports by user code
< Back to List
VOICE DIALER FEATURES
- Completely solid state, no tape or moving parts to wear or
break
- Voice dialer is delayed by 5 minutes if digital dialer is
used to allow central station to call back
- Dials up to 8 user programmable numbers and reports type
and location of alarm
- Called party can cancel dial out by entering code
- OmniLT can call pagers, and be programmed to make a voice
call based on a non-alarm event (example: call when children arrive
home; call if "no activity" for elderly care)
< Back to List
RELIABILITY FEATURES
- Designed for continuous trouble-free operation
- Verifies smoke detectors by cycling power and confirming
smoke alarm
- System reads resistance of each zone independently to
detect trouble due to faulty sensor or wiring before it causes false alarms
- Pulse count feature precludes false alarms due to static,
transients and lightning
- Programmable delay to preclude false alarms from user error
- All inputs and outputs protected against static, RFI,
surges, and lightning by use of impedance limits, spark gaps, TRANZORB surge
arrestors, RC filters, MOVs, bypass capacitors and grounded shields
- Watchdog timer, non volatile EEPROM storage for ALL
programs, self diagnostic software, low voltage cut out, self protecting power
supply forsystem integrity
< Back to List
EASE OF USE FEATURES
- Text descriptions for all zones, units, codes, and macros
- Voice descriptions on telephone
- Console display shows menus to guide users during use
- Minimum keystrokes for common functions
- Quick mode change feature
- Optional wireless keyfob for arming and control available
- Web Browser Graphical Display (HAI Web-Link II) available
< Back to List
TECHNICAL
- Power supply: Requires 16 VAC transformer, 50/60 Hz
- Recommended battery: 12 V, 4 Ah sealed rechargeable
< Back to List
COMPUTER INTERFACE
- Built in Omni-Link serial interface, with jumper selectable
RS-232 or RS-485. Can be used for programming, connection to HAI
Web-LinkII, personal computers, Connectivity Partner options
- Built-in modem for local or remote (with security code)
access to system using personal computer
- Everything in Omni can be programmed using HAI PCAccess
software for personal computer
< Back to List
OPTIONS
- HAI Web-Link II Internet and Local Area Network software
(Windows)
- HAI PC Access configuration, monitoring and programming
software (Windows)
- 16 Zone Supervised Wireless Receiver
- 2-Way Voice Module
- 16 Zone / 8 Output hardwire expansion card
- ALC Hardwire Lighting Control Module
< Back to List
APPROVALS
- UL Residential Fire and Burglary
- FCC Part 15J, Part 68
- IS-60 (Canada)
- California State Fire Marshall
- CE (European Standard)
< Back to List
HAIPROMO12
AUTOMATION FEATURES
Controls up to 72 different
lights, appliances or groups: 64 via power line carrier control modules or optional ALC
hardwire lighting modules, 8 hardwired to Omni II controller
Temperature control for 4
HAI Omnistat thermostats
Omni II sends time, outdoor
temperature to thermostats for display
Time, Sunrise, Sunset,
outdoor temperature display
Status display (On, off,
level, mode, heat, cool, fan, temperature, etc.)
Temperature control for
other items or existing thermostats using up to 8
Temperature Sensors or PESMs
2-Way X-10 and ALC allows
Omni II to receive signals for use as program triggers, features collision detection and
retry for reliability
Lights can be set to scenes
of varying brightness, with Level, Ramp and Scene Support for architectural quality
lighting control
Lights, control outputs,
temperatures and security modes can be scheduled by time, sunrise, sunset, and date or day
of week and various system events.
- 500 lines of non volatile ACP program storage
Commands (immediate and scheduled) include:
Event button capability ("Scenes" or
"macros") allows a series of commands to be executed at once, to create lighting
scenes, house modes, adjust temperatures, etc., initiated by:
- a console, computer or telephone command
- a zone opened or closed
- a mode change (i.e. day, away, vacation)
- a particular user code entered
- a time schedule, sunrise, sunset
- other internal or external events
Enhanced ACP includes new
commands for "real time pricing" of energy costs, and allows two conditionals
per line for easier programming
Automatic Daylight Saving Time
adjustment
Expansion port for future SCP,
UPnP, LonWorks or other interface
< Back to List
SECURITY FEATURES
16 Zones, expandable to 48 zones:
- supports two 10A06 16 zone hardwire expanders
- HAI supervised wireless receiver (16 zones)
- full selection of security zone types, keyswitch
- outdoor temperature, energy saver module
- temperature control and/or alarm
- auxiliary input for automation use (without security)
- all zones support 4 wire smoke detectors
- zone 1-4 support 2 wire smoke detectors
8 Hardwire Outputs, fully configurable for:
- control output for automation
- temperature control
- long range radio
- armed, OK to arm, and others
LCD Consoles:
- surface, flush and universal models available.
- 4 wire connection, independent operation, 8 maximum.
- configurable beeper, viewing angle, backlighting
Features:
True Partitions: security and
automation can be partitioned into 2 areas
Five modes: off, day, night,
away, vacation
16 user codes with selectable
authority levels
User codes can be made valid
during certain times and days only, for maid, service, etc.
All lights on when alarm is
tripped to frighten intruder away
Outdoor lights flashing when
alarm is tripped to alert neighbors and police
Entry, Exit, outdoor sirens
delays user programmable
Entry delay can be doubled or
quadrupled on a zone to accommodate garage and back doors.
Pre-alarm beeper in console and
separate indoor siren output gives owner time to turn alarm off before outdoor siren is
activated
Two separate, supervised
outputs for indoor and outdoor sirens
System Announces type and
location of alarm with optional 2-Way Voice Module
Auto bypass feature means alarm
won't go off unexpectedly if door or window is left open when the system is armed
Trouble conditions indicated in
English on display
Phone line monitor
Optional wireless receiver is
fully supervised for greatest reliability
High Security mode for
commercial applications
All Fire and Burglary zones are
fully supervised
Event Log with Time & Date
< Back to List
TELEPHONE CONTROL FEATURES
Works with Touch Tone phones
inside or away from the premises with access code
Compatible with answering
machines, answering services
Lockout feature discourages
tampering with system by phone
Listen-in / talk to premises
with optional two way voice module
From any phone, you can:
- change modes, temperatures, macros
- arm/disarm security, bypass and restore zones
- hear complete status of system
- hear event log and help menu
< Back to List
DIGITAL DIALER FEATURES
- Contact ID, 4/2 and 3/1 formats, dual round compared
- Two phone numbers with two account numbers
- Opening/Closing reports by user code
< Back to List
VOICE DIALER FEATURES
- Completely solid state, no tape or moving parts to wear or
break
- Voice dialer is delayed by 5 minutes if digital dialer is
used to allow central station to call back
- Dials up to 8 user programmable numbers and reports type
and location of alarm
- Called party can cancel dial out by entering code
- Omni II can call pagers, and be programmed to make a voice
call based on a non-alarm event (example: call when children arrive home; call if "no
activity" for elderly care)
< Back to List
RELIABILITY FEATURES
- Designed for continuous trouble-free operation
- Verifies smoke detectors by cycling power and confirming
smoke alarm
- System reads resistance of each zone independently to
detect trouble due to faulty sensor or wiring before it causes false alarms
- Fuse-less, short-proof design
- Programmable delay to preclude false alarms from user error
- All inputs and outputs protected against static, RFI,
surges, and lightning by use of impedance limits, spark gaps, TRANZORB surge arrestors, RC
filters, MOVs, bypass capacitors and grounded shields Watchdog timer, non volatile EEPROM
storage for ALL programs, self diagnostic software, low voltage cut out, self protecting
power supply for system integrity
< Back to List
EASE OF USE FEATURES
- Text descriptions for all zones, units, codes, and macros
- Voice descriptions on telephone
- Console display shows menus to guide users during use
- Minimum keystrokes for common functions
- Quick mode change feature
- Optional wireless keyfob for arming and control available
- Web Browser Graphical Display (HAI Web-Link II) available
< Back to List
TECHNICAL
- Power supply: Requires 24 VAC transformer, 50/60 Hz
- Recommended battery: 12 V, 7 Ah sealed rechargeable
< Back to List
COMPUTER INTERFACE
- Built in Omni-Link or Pro-Link serial interface, with
jumper for RS-232 or RS-485. Can be used for programming, connection to HAI Web-Link II,
personal computers and Connectivity Partner options
- Built-in v.22 bis fast modem for local or remote (with
security code) access to system using personal computer
- Everything in Omni II can be programmed using HAI PC Access
software for personal computer
< Back to List
OPTIONS
- HAI Web-Link II Internet and Local Area Network software
(Windows)
- HAI PC Access configuration, monitoring and programming
software (Windows)
- Supervised Wireless Receiver, 2-way voice module.
- Additional Serial Board
- 16 Zone hardwire expansion card
- ALC Hardwire Lighting Control Module
< Back to List
APPROVALS
- UL Residential Fire and Burglary
- UL Commercial Burglary
- FCC (USA)
- ICCS-03 (Canada)
- California State Fire Marshall
- CE (Europe): Electromagnetic Compatibility, Emissions and
Immunity
< Back to List
|